GX
                                          
                  Solar simulator for PV module / DKSMT Series
 
Output measurement method for crystalline modules accordance with IEC60891/JIS C 8914 standard
Solar simulator accordance with IEC60904-9/JIS C 8912 standards
Output characteristic measurement system for crystalline solar cell modules
Available in R&D and mass production lines
Irradiation range: 1,200mm x 2,200mm applicable.
Solar simulator for PV module( Inspection equipment for crystalline solar cell module characteristics )
 
- Standard structure
- 
- Automatic mass production mode
- Manual measurement mode
- Calibration for automatic irradiation.
- Repeatability measurement function
- Registration of multiple varieties
- Rank Settings
- Set each parameter and save data
- Self-check function of I-V tester
 
- Accessories
- 
- Class AAA solar simulator
- I-V tester and PC included OS(Windows 10)
- Monitor cell (with temperature control function)
- Temperature measurement unit
- Includes UPS
 
Specifications of I-V tester
- Power source
- 1φ AC200V to 220V, 50/60Hz 3000VA or less
- I-V Tester
- 
Voltage output Voltage output range 30V range:-0.3V to +30V 
 300V range: -0.3V to +300VCurrent output range -0.3 A to +20 A Maximum output capacity 400W Setting resolution 1/30000 of range Setting accuracy ±(0.1% of range + 0.1% of setting value) Voltage measurements Measurement range 3V range: -0.3V to +3V 
 7.5 V range: -0.3 V to +7.5 V
 15V range: -0.3V to +15V
 30V range: -0.3V to +30V
 75V range: -0.3V to +75V
 150V range: -0.3V to +150V
 300V range: -0.3V to +300VMeasurement resolution 1/30000 of range Measurement accuracy ±(0.1% of range + 0.1% of measured value) Current measurement Measuring range 20 A, 10 A, 5 A, 2.5 A, 200 mA Measurement resolution 1/20000 of range Measurement accuracy ±(0.1% of range + 0.1% of measured value) 
- irradiance measurement
- Measurement range - ±200mA - Measurement resolution - ±0.02mA - Measurement accuracy - ±(0.2mA + 0.1% of measured value) 
- Temperature measurement
- Measurement points - 3 measurement points (module, monitor cell and room temperature) 
- Others
- OS - Windows 10 Professional 
- Dimensions W x D x H (mm)
- W×D×H (mm)
 580 mm x 1700 mm x 700 mm not including protrusions
Specifications of the solar simulator
| Spectral match (Class A) | AM1.5G within ±25% | 
|---|---|
| Temporal Instability(Class A) | within ±1% | 
| Non-uniformity of irradiance(Class A) | within ±2% | 
| Effective irradiation area up to | ~1100mm×2000mm | 
| Pulse light irradiation | time : up to10ms or up to100ms *Depends on the model. | 
| Lamp life | averages 100,000 flashes | 
| Measurement interval | Minimum 15 seconds (90 seconds when initially charged) | 
Spectral match
 